time:2018-11-29 source:Author Views:154
Something happened! ! !
24th morning
A fire broke out in a factory in Huangjiang Town, Dongguan
The raging fire billows and thick smoke obscures the sky
The upper part of the whole building is burning
The incident factory is located at No. 19, Jinlang First Street, Diaolang Village, Huangjiang Town
The fire at the scene was very rapid
According to official reports, the building that caught fire was a 4-story factory building, covering an area of about 1,000 square meters. The fire site was a metal shed on the fourth floor. The main burning materials were stationery, cardboard boxes and other items. The fire area was about 400 square meters without personnel. casualties.
After the fire broke out, due to the ferocity of the fire, after receiving an alarm at 07:35, the Dongguan Fire Detachment Command Center immediately dispatched 11 fire engines from Huangjiang, Changping, Zhangmutou, and Dalang Fire Brigades, and 50 firefighters rushed to the scene for disposal. Arrived at the scene at 7:44. The fire was brought under control at 09:00, and the open fire was extinguished at 9:25. The cause of the fire and property damage are under investigation.
Dry weather in autumn and winter
Prone to fire
Whether it’s the factory or home
Pay attention to fire prevention!
The following editor will share with you the fire prevention measures in the factory
1. Implement fire protection responsibilities and strengthen fire management
1. Improve the fire safety management organization, identify responsible persons at all levels, formulate and improve fire safety regulations, increase fire protection investment, strengthen daily fire management, eliminate fire protection violations, and rectify fire hazards;
2. Develop a fire protection work plan, conduct monthly fire safety inspections, strengthen daily fire protection inspections, identify key fire prevention parts, clarify inspection content, and promptly instruct relevant workshop teams to correct problems when problems are found.
2. Strengthen fire protection propaganda, education, training and exercises
1. Carry out a fire-fighting knowledge training for all employees, focusing on training on post fire-prevention techniques, operating procedures, methods of using fire extinguishers and hydrants, evacuation knowledge, and basic fire protection laws, regulations and rules
2. Organize a fire drill among all employees to practice fire fighting skills and evacuation skills.
3. Improve technical preventive measures
1. Conduct an analysis of the fire hazard of various parts and positions of the factory, find out the weak links, and formulate targeted preventive measures;
2. Inspect and improve the fire alarm system, automatic fire extinguishing system, fire signs and emergency lighting, fire evacuation and fire zone, smoke zone, fire truck passage, fire shutter, smoke prevention system, emergency fire broadcast and fire extinguisher, etc. , Ensure good condition;
3. Install monitoring equipment and link with fire-fighting facilities to detect and eliminate fire hazards early.
Fourth, strengthen fire source supervision
1. Carefully analyze the parts of the factory that can generate fire sources, and take measures to prevent them one by one;
2. Pay special attention to the selection, quality and daily management of wires and electrical appliances;
3. Approve the use of open flames, especially electrical welding, equipment maintenance, building decoration, etc.;
4. Check the lightning protection and anti-static facilities to ensure they are in good condition;
5. Check whether there are fire-proof and explosion-proof measures in the places prone to sparks and flammable and explosive gases during production.
In the furniture industry, most media are flammable and explosive, and static electricity is often generated and accumulated during their production, transportation, storage and use. If these charges cannot be discharged in time and gradually accumulate to a certain extent, electrostatic discharge is very easy to occur, igniting flammable and explosive gas, liquid vapor or a flammable mixture formed by suspended dust and air, resulting in fire or even explosion accidents, which will endanger people. Safety, affecting normal production. For the furniture industry, the main goal of electrostatic safety protection is to prevent fire and explosion. Today I will share with you some knowledge about the hazards and protection of static electricity.
How to prevent static electricity in the furniture industry
1. The operation workshop needs to open the doors and windows when going to work, keep good ventilation in the operation workshop, and prevent the accumulation of flammable gas to a certain concentration.
2. The operation workshop should be properly sprinkled with water, and a humidifier can also be used to increase the air humidity in the operation workshop, which can effectively prevent the accumulation of static electricity.
3. There must be enough fire extinguishers in the operation workshop
4. The operation workshop must be cleaned and cleaned frequently to reduce the concentration of dust and avoid static electricity caused by dust friction.
5. The master in the operating workshop should wear cotton overalls and cotton gloves, and avoid wearing chemical fiber clothing. Try not to take off work clothes in the operation workshop. The master in the operation workshop should keep the good habits of washing hair, bathing frequently, and rubbing moisturizers frequently.
6. In winter, there is a lot of static electricity between sponge and spring bag. When handling, stacking and covering, it should be handled with care to minimize the friction between sponge and sponge, spring bag, non-woven fabric and other materials to avoid Static sparks are generated due to friction, rolling, and impact.
7. When covering the sponge at the end of the bonding sponge spring package process, leave one side unsealed first, and then squeeze in order from the sealed side to the unsealed side. It is not possible to bond the entire surface at the same time, and then press hard, because after the entire surface is bonded at the same time, it is difficult to discharge the combustible gas volatilized by spraying at this time. When a certain concentration is reached, the sponge and spring package that are squeezed hard may be possible Sparks caused by electrostatic friction ignite the sponge and cause fire. Avoid flapping the spring bag.
Highly recommended flame retardant spray glue
Features
Strong adhesion, high solid content, high temperature resistance, strong flame retardancy, low odor, environmental protection, and glue saving
Applicable materials
It is used to bond fire-retardant sofas, fire-retardant swivel chairs, fire-retardant sponge, fire-retardant fabrics and other materials.
Operation precautions
Double-sided spraying, after spraying, it needs to be left in the air for 1-3 minutes before bonding. Uneven spraying, glue accumulation, lack of glue, and improper pressing may cause degumming and glue opening.